Xiamen GTL Power System Co.,Ltd.

# call at +86-592-7196398

# leave a message gtl@cngtl.com

banner
Product Knowledge
home

News

Product Knowledge

Configuration and market application of multi-voltage units

categories

hot products

  • Clip-On Reefer Diesel Generator set

    RGC15/ Clip-On Reefer Generator The model RGC15 mounts to properly equipped ISO containers, in front of the refrigeration unit's upper face. Generator sets are typically provided with "pin” mounting to attach to the container’s header rail. Clamp mounting to the corner casting of the container is available as an option. In either case, when mounted, the RGC15 envelope allows acce1 more

  • Silent  Undermount Reefer  Generator

    RGU15/ Underslung Reefer generator The underslung RGU15 is designed for applications requiring under mounting of the container chassis between the I-beams to allow for maximum road clearnance and even weight distribution. Four-point quick disconnect mounting hardware allows it to be easily mounted and removed. more

  • LED Hydraulic Lighting Towers

    4LT4000H9 MH/ Hydraulic 9m 4*1000W Metal halide lamp diesel-driven lighting tower GTL ‘ s hydraulic lighting towers, lamp post can be raised up to 9 m, resistance to wind force 9, equipped with brushless alternator, each lamp holder has independent control switch. Suitable for railway, electric, public security, oil fields, metallurgy, petrochemical enterprises and other large-scale construction operations, accident repair, resc1 more

  • Solar Light Tower

    4SLT400M7 4*100W LED Solar Light Tower 4SIT400M7 LED GTL Lighting Towers is arugged, mobile outdoor light systems that providhigh-intensity, bright white lighting on-demand, where and when you need4SLT400M7 LED lighting towers is durablle and reliable. lt can cover up to 2304 m2 of lightin.area, suitable for any terrain and environment. The height of the lighting tower can extend tc7met1 more

  • GTL Cummins diesel generator

    Cummins 20~115 KVA Silent & Open Gen-set Cummins is the world's largest independent diesel engine manufacturer, with the industry's largest power range of diesel and natural gas engine line. GTL cummins unit adopts DCEC/CCEC/XCEC and original engine as driving power, with high overall reliability, long continuous operation time and low fuel consumption. In particular, cummins' worldwide s1 more

  • Diesel Screw Air Compressor

    185CFM 7Bar Diesel Screw Air Compressor A rotary-screw compressor is a type of gas compressor, such as an air compressor, that uses a rotary-type positive-displacement mechanism. They are commonly used to replace piston compressors where large volumes of high-pressure air are needed, either for large industrial applications such as chillers, or to operate high-power air tools such as jac1 more

Leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Configuration and market application of multi-voltage units

  • 2022-05-31
configuration of multi-voltage genset
1.1 Summary of multiple voltage genset

Due to the different requirements of the power generator set application or the diversity of the input power supply voltage of the user terminal load.At this time, it is necessary to have a generator set with multiple voltage AC power outputs.

GTL 1500KW/220V 3P/4W--380V 3P 4W multiple voltage Generator set
1.2 Classification of multiple voltage output generator sets
a. The load method of the small power section can be realized by a universal transfer switch. This way can support switching of 3 different voltages.
b. Users who have professional electrical maintenance of generator sets on site can choose manual modification. It can be realized by changing the connection point of the copper bar, this method can support the changing of 3 different voltages.
c. Optional application of dual power switch, it can be realized by changing the wiring mode of the generator winding and automatically switching the voltage. This method can support the switch of 2 different voltages.


Universal conversion manual switching mode  Manually change the copper bus way  Dual power switching changes winding wiring

1.3 configuration of multiple voltage generator sets

A. Universal conversion manual switching mode: the main circuit breaker of the generator set (the rated current is calculated according to the minimum voltage segment and the minimum number of phases),universal transfer switch, the main circuit breaker to the universal transfer switch and the universal transfer switch to the generator connection cable, the control system has a variety of voltage properties protection, AVR wiring adjustment.

B. Manual change the copper bus way:The main circuit breaker of the generator set (the rated current is calculated according to the minimum voltage segment and the minimum number of phases), a variety of voltage switching insulation boards, the main circuit breaker to the insulation board and the insulation board to the generator connection cable, the control system has a variety of voltage properties Protection, wiring adjustment for AVR

C.Dual power switching to change the winding wiring method: The main circuit breaker of the generator set (the rated current is calculated according to the minimum voltage segment and the minimum number of phases), 2 double power switches and their control components, the main circuit breaker to the double power switch and the double power switch to the generator connection cable, the control system has A variety of voltage properties protection, AVR wiring adjustment.

1.4 Alternator selection requirements for multiple voltage generator sets

The working principle of various voltage switching: Since the 12-wire generator winding can be adjusted, according to the generator winding wiring schematic diagram, it can output: 1. The series star winding wiring output:380V-415V/50Hz and 380V-480V/60HZ;2. Parallel star winding wiring output:190V-208V/50HZ and190V-240V/60HZ: Double delta winding wiring output: 220V-240V/50HZ and 220V-240V/60HZ.





The alternator selection requirements for various voltage generator sets:

1. The generator set winding needs 12-wire output; 2. The AVR needs to have the voltage trimmer potentiometer signal output.

1.5 Market application scenarios of multiple voltage generator set Market application of multiple voltage generator sets:1. Generator set rental market;

2.The power input voltage of the user terminal equipment is various;

3. The user terminal equipment has single-phase load and three-phase load, but they are not used at the same time;

4. The power grid output voltage of local countries is various.